Page tree

This page has not yet been translated to English.

Skip to end of banner
Go to start of banner
Skip to end of metadata
Go to start of metadata

 

New functions:

IconShort textElementReferenceVersion

Sankey Manager

  • Structured and informative overview of all existing Sankey diagrams. 
  • Creating, copying, grouping and deleting individual Sankey diagrams.
  • Direct access to the Sankey Configurator.
  • “Sankey diagram” preview function in the dialogue window.
  • Loss management.
  • Associated value (e.g. currency).
  • Relative value (percentage with consumption selection).

 

 

Sankey

Ultimate edition

GridVis Energy web interface

7.1.0

Sankey Configurator

  • The Sankey Configurator creates Sankey logics that the system uses to draw Sankey diagrams.
  • Choice between “single-colour” and “transition” colour modes.
  • Support of the “live” and “historical” modes.
  • Selection of the time period.
  • Simple and intuitive group and connection configuration.
  • “Sankey diagram” preview function.

 

Sankey

Ultimate edition

GridVis Energy web interface

7.1.0

Sankey Widget

  • Creating Sankey diagrams as a Sankey Widget on the dashboard.
  • Free choice of position and size.
  • Showing and hiding of the header.

 

Sankey

Ultimate edition

GridVis Energy web interface

7.1.0

KPI Manager

  • Display and overview of all KPIs (key performance indicators).
  • “3-stage evaluation system” display.
  • “Person responsible” display.
  • Creating, copying, grouping and deleting KPIs that have been created.
  • Direct access to the KPI Configurator.
  • “KPI evaluation” preview function in the dialogue window.

 

 

KPI

Ultimate edition

GridVis Energy web interface

7.1.0

KPI Configurator

  • Selection of the formula for creating KPIs.
  • Selection of the “person responsible” (user).
  • Selection of the time period.
  • Selection of the “comparison period”.
  • 3-stage evaluation system with traffic light animation.
  • Selection of the trend consumption.
  • Parameter assignment with measured values, virtual devices or with values from manual input.
  • “KPI evaluation” preview function.

 

 

KPI

Ultimate edition

GridVis Energy web interface

7.1.0

 KPI Widget

  • Creating KPIs as a KPI Widget on the dashboard.
  • Free choice of position and size.
  • Showing and hiding of the header.
  • Displaying the KPI Widget as either a bar graph or table.

 

 

 

KPI

Ultimate edition

GridVis Energy web interface

7.1.0

Colour Picker

  • RGB and Hex input.
  • Colour spectrum slider.
  • Colour suggestions from the last selected colours.

 

 

Widgets

Ultimate edition

GridVis Energy web interface

7.1.0

Desktop device list

  • Optimised device list.
  • New device selection column in the overview window. All selected devices at a glance.
  • Line “highlighting”. 
  • Integrated XLS export. The column and device selection determines the XLS data exported.
  • “Hot Key” function: “All selections" < CTRL > + < A > or "Cancel selection” < Esc >.
  • “Hot Key” function for the area “Selection” < CTRL + Shift >.
  • New column "GridVis-ID".
  • Persistent user settings.
  • Customer-specific column selection.

 

 

Device list

All editions

Desktop

7.1.0
 

Deactivating devices

  • Activating and deactivating devices in the device list.
  • Deactivated devices do not establish any communication. Readout and online logging are deactivated.
  • Deactivated devices do not appear in the “Install App” or “Firmware” dialogue.





Device list

Device tree

All editions

Desktop

7.1.0
 

Manual Input (MI) - calculation

  • New mode for the calculation of user-defined values.
  • Interval.
  • Energy calculation with backstop.
  • Energy calculation without backstop.
  • Maximum.
  • Arithmetic average.
  • Total.

 

MI

From the Professional edition onwards

Desktop

 
 

Function enhancement for "consumption reports"

  • PDF output of the consumption reports (new from GridVis 7 onwards).
Energy reports

All editions

Reports

 

7.1.0
 

Export of the energy/performance values V2 (CSV)

  • CSV export for energy values.

 

 

Energy export

All editions

Exports

7.1.0
 

Error Log with time stamp

  • Error logs recorded with time stamps.

 

Error log

All editions

7.1.0
 

4-quadrant energy measuring for the UMG605 / UMG511

Measured values

All editions

7.1.0

 


 

Announcements

IconShort textElementReferenceDate

From spring 2017:

  • No support for the Microsoft IE 8, 9, 10 browser versions (discontinued by Microsoft).
  • Replaced by the Microsoft Edge and IE 11 browser versions.
Internet Explorer Browser 

The XLS export replaces the connection report in the device list.

Note:
The connection report can be activated via the parameter  -J-Dpasw-feature-deviceoverview-connection-report=true in the configuration file "GridVis.conf".

Device listExport 
The GridVis 7.2 is planned for calendar week 45, 2016 (Beta release).
The focus is on time management and an improved Dashboard Editor.
Next releaseVersion 

 

 


 

Optimizations and bug fixes

IconShort textElementReferenceDate
Currency information - SFR has been changed to CHF.WidgetGridVis Energy7.1.0
Widget name - changed.WidgetGridVis Energy7.1.0

Heat Map - bug fixes and stability improvements.

WidgetGridVis Energy7.1.0

Dashboard Editor - bug fixes and stability improvements.

EditorGridVis Energy7.1.0

Animation for icons and tabs.

AnimationGridVis Energy7.1.0

Last login is stored in the browser

LoginGridVis Energy7.1.0

Online measured values - bug fix in the measured value selection

WidgetGridVis Energy7.1.0

Sankey loss management - enhancement of the Sankey diagram

Sankey

GridVis Energy7.1.1

Sankey associated value - enhancement of the Sankey diagram

Sankey

GridVis Energy7.1.1

Sankey relative values - enhancement of the Sankey diagram

Sankey

GridVis Energy7.1.1

Memory problem on the Graph Set resolved

Graph Set

GridVis Desktop7.1.1

Bug fix - Transient configuration 

Device configuration

GridVis Desktop7.1.1

Bug fix - Analogue output configuration

Device configuration

GridVis Desktop7.1.1

Tab Navigator added

Dashboards

GridVis Energy7.1.1

drag pointer function - UMG96RM

Configuration

GridVis Desktop7.1.1

Donut Widget displays the values of MIs (manual input)

Widget

GridVis Desktop7.1.1

Improvements & optimisations - Memory management

System

System7.1.2

Optimisation - Energy calculation for user-defined values

System

System7.1.2

Bug fix - Scaling in the bar graph

Widget

GridVis Energy7.1.2

Optimisation - Places after the decimal point in the pie chart

Widget

GridVis Energy7.1.2

Bug fix - Performance calculation for the S0 input

UMG 96RM-E/CBM/P

System7.1.2

Functional enhancement - Transparent link

Widget

GridVis Energy7.1.2

Optimisation - Energy values now use the basic unit in "k"

Various functions

System7.1.3

Bug fix - Device list navigation

Device list

GridVis Desktop7.1.3

Bug fix - Calculation with energy values without a backstop

Various functions

System7.1.3

Bug fix - Sankey Configurator

Sankey

GridVis Energy7.1.4

Bug fix - Internet Explorer 11 and older versions

Display

GridVis Energy7.1.4

Bug fix - Special characters in the project name

AdministrationGridVis Desktop7.1.4

Bug fix - Device list

Device list

GridVis Desktop7.1.4

System & stability improvements

System

System7.1.4

Bug fix - Time planning report

Reports

GridVis Desktop7.1.4

Bug fix - UMG96S displaying negative active energy

UMG96S

System7.1.4

Web-based help updated

Help

Web-based help7.1.4

Bug fix - KPI display errors when divided by 0

KPI

GridVis Energy7.1.5

Optimisation of the online logging

System

System7.1.5

Bug fix - Measured value selection for reports

Reports

System7.1.5

Bug fix in System management for IE9

Internet Explorer

GridVis Energy7.1.5

Bug fix in the virtual device, the value 0 can be set as the default

VD

GridVis Desktop7.1.5

Bug fix in the wizard for database actions

Database

System7.1.5
Feature optimization multiple project selection for KPI ManagerKPIGridVis Energy7.1.6
Feature optimization number limit in the alarm listAlarmsSystem7.1.6
Feature optimization multiple project selection for Sankey ManagerSankeyGridVis Energy7.1.6
Function upgrade text format live valuesWidgetGridVis Energy7.1.6
Bug fixes energy values associated with constants in the virtual device (VD)FunctionSystem7.1.6
Function upgrade device sync log with time stampsLogsSystem7.1.6
Function upgrade database action delete alarmsAlarmsGridVis Desktop7.1.6
Bug fixes CBEMA-Graph and Graph-SetGraphGridVis Desktop7.1.6
Bug fixes overview BacNet clearing UMG96RM-EDeviceGridVis Desktop7.1.6
Bug fixes bar chart widgetWidgetGridVis Energy7.1.6
Bug fixes temperature input configuration UMG 96RM-EDeviceGridVis Desktop7.1.6
Bug fixes CT (current transformer) configuration UMG 96SDeviceGridVis Desktop7.1.6
Feature optimization live value widgetWidgetGridVis Energy7.1.6
Bug fixes Prodata 2 configurationDeviceGridVis Desktop7.1.6
Bug fix in line chart configurationWidgetGridVis Energy7.1.6
Feature optimization automatic device synchronisationSystemSystem7.1.6
Function upgrade connection type "Easy Gateway" for UMG96RM-EDeviceGridVis Desktop7.1.6
Function upgrade time selection graph-setGraphGridVis Desktop7.1.6
Bug fix main project system settingsSystem GridVis Energy7.1.6
Bug fixes line chart tooltip functionWidgetGridVis Energy7.1.6
Function upgrade phase diagram UMG96RM-PNDeviceGridVis Desktop7.1.6
Function modification energy values basic unit in kWh/kVar/kVASystemSystem7.1.6
Bug fixes UMG509/UMG512 L5, L6 labelingDeviceGridVis Desktop7.1.6
Feature optimization line chart scalingWidgetGridVis Energy7.1.6
Function upgrade UMG103-CBMDeviceSystem7.1.6
Bug fixes alarm overview e-mailAlarmsSystem7.1.6
Feature upgrade UMG20CM with memoryDeviceSystem7.1.6
Bug fixes KPI trend calculationKPIGridVis Energy7.1.6
Bug fixes MIN real power maintained in energy overviewOverviewGridVis Desktop7.1.6
Bug fixes Template selectionDashboardsGridVis Energy7.1.7
Bug fixes Min / Max OverviewWidgetGridVis Energy7.1.7

 


 

Subject to technical changes.
The content, performance features and diagrams provided in the software description are not always reflective of the actual cases and will change, e.g. with the ongoing development of the software. The content has been compiled with the utmost care and is based on the latest information available to us. Errors cannot be excluded.
The desired performance features and delivery conditions are only binding if these are expressly agreed upon when the contract is concluded.
The trade names, brand names and trade descriptions are subject to the guidelines of the respective manufacturer. Janitza electronics GmbH does not guarantee to keep this software description up-to-date. For further current information and specifications, see www.janitza.de.

 

  • No labels